130-280KW Cummins Generator

Benefits
Function stability credibility, service convenience;
Low operating cost results in optional economy;
Gets the job done wherever you are;
Ease of installation, operation and maintenance.
| Genset Model | Products Name | ||
| MCL130-2 | 130KW Cummins Generator | ||
| MCL180-2 | 180KW Cummins Generator | ||
| MCL205-2 | 205KW Cummins Generator | ||
| MCL250-2 | 250KW Cummins Generator | ||
| MCL280-2 | 280KW Cummins Generator | ||
| Prime power | 100 kVA | ||
| Standby power | 110 kVA | ||
| Rated speed | 1500 RPM | ||
| Output frequency | 50 Hz | ||
| Phase | 3 | ||
| Rated voltage | 400 V | ||
| Engine model | 6BT5.9-G2 | ||
| Alternator model | LYG 274B | ||
| Fuel consumption of 100% load | 22 Litres/h | ||
| Fuel consumption of 75% load | 17 Litres/h | ||
| Voltage regulation rate | ≤±1% | ||
| Random voltage variation | ≤±1% | ||
| Frequency regulation rate | ≤±5% | ||
| Random frequency variation | ≤±0.5% |
Prime Power:
This rating is for the supply of continuous electrical power (at variable load). There is no limit on the annual hours of operation and 10% overload power can be supplied for 1 hour in 12.
Standby power:
This rating is for the supply of continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted.
Rated voltage:
Available with customer requirements.
| Dimension and Weight | ||
| Length(L) | mm | 2450 |
| Width(W) | mm | 800 |
| Height(H) | mm | 1465 |
| Weight | kg | 1080 |
| Tank capacity | L | 220 |
| Environment Condition | ||
| Environment temperature | oC | ≤50 |
| Relative humidity | % | ≤90 |
| Altitude | m | ≤1000 |
| Engine Specifications | ||
| Engine model | 6BT5.9-G2 | |
| Engine manufacturer | Cummins | |
| Number of cylinders | 6 | |
| Cylinder arrangement | Vertical in-line | |
| Cycle | Four stroke | |
| Aspiration | Turbocharged | |
| Bore×Stroke (mm×mm) | 102 x 120 | |
| Displacement (Liter) | 5.9 | |
| Compression Ratio | 17.5:1 | |
| Prime power/speed (kW/RPM) | 92/1500 | |
| Standby power/speed (kW/RPM) | 100/1500 | |
| Speed governor | Electrical | |
| Cooling system | Forced Water Cooling Cycle | |
| Steady speed droop (%) | ≤1% | |
| Total lubrication system capacity/L | 16.4 | |
| Coolant capacity (engine only)L | 9.1 | |
| Fuel consumption load (g/kWh) | 214 (at 1500RPM) | |
| Starter motor | DC24V | |
| Alternator | AC24V | |
| Alternator Specifications | ||
|
Alternator model |
LYG 354B | |
| Alternator manufacturer | Lisite | |
| Exciter type | Single bearing, Brushless | |
| Rated output prime power | 181 kVA | |
| Rated speed | 1500 RPM | |
| Rated frequency | 50 Hz | |
| Phase | 3 | |
| Rated voltage | 400 V | |
| Power factor | 0.8 | |
| Voltage adjust range | ≥5% | |
| Voltage regulation NL-FL | ≤±1% | |
| Insulation grade | H | |
| Protection grade | IP22 | |
Remark
Alternator option:
Other alternator manufacturer: Stamford, Leroy Somer, Marathon and Mecc Alte.
Control System DSE3110

All TAIZHOU YP Machinery Electronic Technology Co., Ltd genset have a control cubicle (the deepsea controller DSE3110 as standard) mounted on a isolated support, which has the following features:
1.Electronic digital control module with monitoring/control facility and warning indicators;
2.Automatic shutdown protection;
3.Emergency stop button (lock-down type);
4.AC output circuit breaker with over-current protection;
5.DC circuit control switch.
The control module gives digital readouts of:
1. Generator voltage;
2. Output frequency;
3. Engine speed;
4. Battery voltage;
5. Engine hours run.
Note:
1. The engine coolant temperature used temperature meter display;
2. The engine oil pressure used oil pressure meter display;
3. Generator current used current meter display and used change switch for each phase displayed separately
The control module has indicators for failure information:
1. Overspeed/underspeed,
2. Emergency stop
3. Low oil pressure;
4. High water temperature
5. Failure to start
6. Battery charger failure
Automatic shutdown occurs under:
1. Low engine oil pressure;
2. High engine water temperature;
3. Overspeed/underspeed;
Failure to start after three attempts.
The controller option:
Remark: the controller detail information please refer to the file Control System Choice
Generator Set Options and Accessories

Generator set
Silence generator set
Trailer generator set
Single phase generator set
ABB MCCB circuit breaker
Fuel system
12 hour base tank(single wall)
24 hour base tank(single wall)
Dual wall base fuel tank
Outside fuel tank
Exhaust system
Residential exhaust silencer
Alternator
PMG excitation
Space heater
Low environment temperature
Water heater
Oil heater
Battery heater
Control system
AMF function
ATS control cabinet
Multiple generator automatic synchrorising
130-280KW Cummins Generator Manufacturer,Supplier&Factory search on:Google, Yahoo, Msn
TAIZHOU YP Machinery Electronic Technology Co., Ltd
Add:No. 111 Luda Rd. Luyuan Industrial Tai Zhou China
City/Province:Shanghai/Shanghai
Country/Region:China
Zip/Postal Code:
Tel:86-576-61049555
Fax:86-576-61049556
E-mail:kentdoherty@hotmail.com













